IBC container (EU) washing through the throat and P86, P110, P510, P1010
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
| Highlighted rows show differences | ![]() | ![]() | ![]() | ![]() |
|---|---|---|---|---|
| Manufacturer | TEHNIKA VYSOKOGO DAVLENIIA | ZIVIL | ZIVIL | FELETI |
| Model | — | P86 | — | — |
| Manufacturer country | Russia | Russia | Russia | Belarus |
| Equipment type | Washing machine | Washing machine | Washing machine | Washing machine |
| Volume, L | — | 1,000 | 1,000 | 190 |
| Power, kW | — | 2.2 | 2.2 | 4 |
| Configurations | — | P 86, P 110, P 510, P 1010 | P 85, P 105 R, P 505, P 1005 | — |
| Parameter | Value | — | — | — |
| Expenditure | 21 L/min | — | — | — |
| Head pressure | ≈ 130 bar | — | — | — |
| Power supply | 3~400 V, 50 Hz, 5.5 kW | — | — | — |
| Cycle to Cube | 8 min - 2018 Test | — | — | — |
| Water to Cube | UM 170L - Calculation for a model solution | — | — | — |
| Cubes in shifts | 26 - 30 — Model Decision calculation | — | — | — |
| Water at the entrance | 22 l/min, 1.5 - 6 bar, to 50 °C | — | — | — |
| Cubes on shift, one place. | E 35 — Calculation for the Model Decision | — | — | — |
| Cubes on shift, two seats. | E 49 — Calculation for the Model Decision | — | — | — |
| IBC Post: flow rate | 21 L/min | — | — | — |
| Power supply of module | 3~400 V, 50 Hz, 16.5 kW | — | — | — |
| Water on module | 66 l/min, 2 - 6 bar, to 50 °C, D32 input | — | — | — |
| Pump module | in a room not less than +1 °C | — | — | — |
| Dimensions from the outside | ~ 1,900 x 1,800 x 2,950 mm - Calculation for the model solution | — | — | — |
| Cube | 1,200 x 1,000 mm in any orientation, 1000 and 1,250 l | — | — | — |
| Question | What to Choose | — | — | — |
| How many cubes per shift | Up to 26 - 30, occasionally a mobile kit; up to ~35 post 21 l/min; up to ~47 post 42 l/min; more than two seats per pump (EU 49 and ~ 76) | — | — | — |
| One product or many | One product: manual post with timer; different products and programmes: automatic | — | — | — |
| What was in the cube? | lycing, suspensions, syrup — basic performance; acids and chlorides — chemical execution and chamber; LVG and solvent paints — only after gas-freeing or on a separate project | — | — | — |
| People, acids work alongside you. | Hind chamber: Sprays and aerosol remain inside | — | — | — |
| Food and chemical cubes | in different posts; food not on mobile set | — | — | — |
| Is there a tank car wash nearby? | Yes - IBC post from the same pump module; no - separate post | — | — | — |
| Fats and oils | heating up to 60 °C - project | — | — | — |
| Winter and open area | pump module - room not less than +1 °C; post - warm box or heated panel | — | — | — |
| Power, P 86 | — | 2.2 kW | — | — |
| Power, P 110 | — | 4 kW | — | — |
| Power, P 510 | — | 7.5 kW | — | — |
| Power, P 1010 | — | 15 kW | — | — |
| Voltage, P 86 | — | 240/400 V | — | — |
| Voltage, P 110 | — | 240/400 V | — | — |
| Voltage, P 510 | — | 240/400 V | — | — |
| Voltage, P 1010 | — | 240/400 V | — | — |
| Dok, P 86 | — | 5.5 A | — | — |
| Dok, P 110 | — | 9.7 A | — | — |
| Dok, P 510 | — | 16.4 A | — | — |
| Dok, P 1010 | — | 29 A | — | — |
| Weight, P 86 | — | 143 kg | — | — |
| Weight, P 110 | — | 258 kg | — | — |
| Weight, P 510 | — | 545 kg | — | — |
| Weight, P 1010 | — | 870 kg | — | — |
| Volume, P 86 | — | 1 m³ | — | — |
| Volume, P 110 | — | 1.5 m³ | — | — |
| Volume, P 510 | — | 2.5 m³ | — | — |
| Volume, P 1010 | — | 3.5 m³ | — | — |
| Water consumption 65 °C, P 86 | — | 0.9 m³/h | — | — |
| Water consumption 65 °C, P 110 | — | 1.2 m³/h | — | — |
| Water consumption 65 °C, P 510 | — | 1.4 m³/h | — | — |
| Water consumption 65 °C, P 1010 | — | 1.8 m³/h | — | — |
| Throughput, P 86 | — | 300 stomachs/hour | — | — |
| Throughput, P 110 | — | 600 stomachs/hour | — | — |
| Throughput, P 510 | — | 1,200 stomachs/hour | — | — |
| Throughput, P 1010 | — | 2,400 stomachs/hour | — | — |
| Power, P 85 | — | — | 2.2 kW | — |
| Power, P 105 R | — | — | 4 kW | — |
| Power, P 505 | — | — | 7.5 kW | — |
| Power, P 1005 | — | — | 15 kW | — |
| Voltage, P 85 | — | — | 240/400 V | — |
| Voltage, P 105 R | — | — | 240/400 V | — |
| Voltage, P 505 | — | — | 240/400 V | — |
| Voltage, P 1005 | — | — | 240/400 V | — |
| Dok, P 85 | — | — | 5.5 A | — |
| Dok, P 105 R | — | — | 9.7 A | — |
| Dok, P 505 | — | — | 16.4 A | — |
| Dok, P 1005 | — | — | 29 A | — |
| Weight, P 85 | — | — | 135 kg | — |
| Weight, P 105 R | — | — | 245 kg | — |
| Weight, P 505 | — | — | 520 kg | — |
| Weight, P 1005 | — | — | 850 kg | — |
| Volume, P 85 | — | — | 1 m³ | — |
| Volume, P 105 R | — | — | 1.5 m³ | — |
| Volume, P 505 | — | — | 2.5 m³ | — |
| Volume, P 1005 | — | — | 3.5 m³ | — |
| Water consumption 65 °C, P 85 | — | — | 0.9 m³/h | — |
| Water consumption 65 °C, P 105 R | — | — | 1.2 m³/h | — |
| Water consumption 65 °C, P 505 | — | — | 1.4 m³/h | — |
| Water consumption 65 °C, P 1005 | — | — | 1.8 m³/h | — |
| Throughput, P 85 | — | — | 15 stomachs/hour | — |
| Throughput, P 105 R | — | — | 30 stomachs/hour | — |
| Throughput, P 505 | — | — | 60 stomachs/hour | — |
| Throughput, P 1005 | — | — | 120 stomachs/hour | — |
| Power of washing pump, kW | — | — | — | 4 |
| Number of washers, unit | — | — | — | 36 |
| Injector capacity, l/min | — | — | — | 285 |
| Volume of container with cleaning solution, eu l | — | — | — | 190 |
| Pressure of the injectors, butter, | — | — | — | 0,38 |
| Number of polishing injectors, unit | — | — | — | 19 |
| Water flow through water spray at network water pressure 0.3 MPa, l/m | — | — | — | 45 |
| Pressure on the rinse head, | — | — | — | 0,3 |
| Moisting solution container | — | — | — | Yes |
| Heat insulation of the washing solution container along the contour | — | — | — | Yes |
| Pollution washing gun (net water submersible) | — | — | — | Yes |
| Maintaining the temperature of the detergent - for KETO electric heating machines - | — | — | — | Yes. |
| Automatically operating time (moisted) of the specified washing and oo cycle | — | — | — | Yes |
| Water discharge after water wash to sewers (without dilution of washing solution) | — | — | — | Optional |
| Automatic subsidy of cleaning agent | — | — | — | Yes |
| Deterioration solution filter | — | — | — | Yes |
| Adding disinfectant to water of bilge | — | — | — | No |
| Power of transmission of the displacement of the framework | — | — | — | 0,55 |
| Power of cleaning solution (for KETO), kW | — | — | — | 24 |
| Separate water pumping and washing | — | — | — | Yes |
| Maximum temperature of the cleaning solution, 0C | — | — | — | 60 |
| Maximum water intake temperature for water polishing 0C | — | — | — | 85 |
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
The comparable values match. Check the available configurations and operating figures for your product.
If volume is your priority, P86, P110, P510, P1010 has the larger stated capacity. Confirm the working load for your product.
If volume is your priority, KRS P 85, P 105 R, P 505 and P 1005 gastric washing machines has the larger stated capacity. Confirm the working load for your product.