1. Home
  2. Compare

Compare models

View summary
Highlighted rows show differences
Air heat exchanger on biomass for dryer
ManufacturerIntermech EngineeringE8E8E8
Model———X150
Manufacturer countryTanzaniaRussiaRussiaRussia
Equipment typeHeat exchangerHeat exchangerHeat exchangerHeat exchanger
Volume, L—60.260.24.6
PTO plate material—254SMO, AISI 304, AISI 316L, Hastelloy C276 and titanium254SMO, AISI 304, AISI 316L, Hastelloy C276 and titanium254SMO, AISI 304, AISI 316L, Hastelloy C276 and titanium
Housing material—09G2C, AISI304, AISI316, AISI32109G2C, AISI304, AISI316, AISI32109G2C, AISI304, AISI316, AISI321
Material—Carbon steel (standard)Carbon steel (standard)Carbon steel (standard)
Design temperature, °C—150150150
Intended use—Industry, E.E., ShipbuildingIndustry, E.E., ShipbuildingIndustry, E.E., Shipbuilding
Design—2-circuit, two-pass, monoblock, eleven-pass, single-pass, flow-through, high-velocity, three-pass, three-circuit and four-pass configurations2-circuit, two-pass, monoblock, eleven-pass, single-pass, flow-through, high-velocity, three-pass, three-circuit and four-pass configurations2-circuit, two-pass, monoblock, eleven-pass, single-pass, flow-through, high-velocity, three-pass, three-circuit and four-pass configurations
Wednesday—Water, oil, liquid foods, ethylene glycol, acids, petroleum products, steam, Freon and alkalisWater, oil, liquid foods, ethylene glycol, acids, petroleum products, steam, Freon and alkalisA pair of condensants.
View—Discretionary plateDiscretionary plateDiscretionary plate
Industry—Nuclear power and refrigeration, municipal utilities, general industry, mining, metallurgy, oil and gas, shipbuilding, chemicals and power generationNuclear power and refrigeration, municipal utilities, general industry, mining, metallurgy, oil and gas, shipbuilding, chemicals and power generationNuclear power and refrigeration, municipal utilities, general industry, mining, metallurgy, oil and gas, shipbuilding, chemicals and power generation
Flow diagram—Single-wheel driveSingle-wheel driveSingle-wheel drive
We're on the warmer side.—SwampSwampWater
Environment on the heated side—WaterWaterWater
Warming-side cost—6.87 th6.87 th11.2 t/h
Heated side flow rate—186.6 kWh186.6 kWh4.67 t/h
Temperature at the entrance on the heating side, °C—120,3120,395
Temperature at the inlet to the heated side, °C—60605
Temperature at the outlet on the hot side, °C—116,7116,770
Temperature at the outlet on the heated side, °C—808065
Hot side pressure losses—21.47 kPa21.47 kPa29.73 kPa
Heated side pressure losses—42.2 kPa42.2 kPa5.76 kPa
Heat load—4 331.7 kW4 331.7 kW280000 kcal/h
Surplus surface area, %—171716,1
Coef, heat transfer—652265224017
Effective area, m2—12122
Number of plates—444450
Connections—FlancFlancCutter
Port cover—AISI 304 stainless steelAISI 304 stainless steel-
Reaction flanges—Flanc 200-16-01-1-B-St. 20-III-dv222 GOST 33259-2015Flanc 200-16-01-1-B-St. 20-III-dv222 GOST 33259-2015-
Design pressure—161610
Test pressure, kg/s/cm2—212114
Net Weight, kg—886,6886,638,8
Internal volume, l—60,260,24,6
Design pressure, bar—25, -125, -125, -1
Operating temperature—200, -40200, -40200, -50
Type of shell of heat exchanger—Carbon steelCarbon steel—
Air temperature at outletUp to 70 °C———
Biomass consumption5 kg/h———
- The type of RIT?———S-32

Pairwise comparison summaries

E8 (Du 200) heat exchanger interchangeable with APV and E8-X150 heat exchanger (Du 150)

  • Volume. E8 (Du 200) heat exchanger interchangeable with APV has the larger stated volume (60.2 L). The stated value for E8-X150 heat exchanger (Du 150) is 4.6 L.
  • Temperature at the entrance on the heating side, °C. E8 (Du 200) heat exchanger interchangeable with APV: 120,3. E8-X150 heat exchanger (Du 150): 95.
  • Temperature at the inlet to the heated side, °C. E8 (Du 200) heat exchanger interchangeable with APV: 60. E8-X150 heat exchanger (Du 150): 5.
  • Temperature at the outlet on the hot side, °C. E8 (Du 200) heat exchanger interchangeable with APV: 116,7. E8-X150 heat exchanger (Du 150): 70.

If volume is your priority, E8 (Du 200) heat exchanger interchangeable with APV has the larger stated capacity. Confirm the working load for your product.

E8 (Du 200) exchanger interchangeable with ARES and E8-X150 heat exchanger (Du 150)

  • Volume. E8 (Du 200) exchanger interchangeable with ARES has the larger stated volume (60.2 L). The stated value for E8-X150 heat exchanger (Du 150) is 4.6 L.
  • Temperature at the entrance on the heating side, °C. E8 (Du 200) exchanger interchangeable with ARES: 120,3. E8-X150 heat exchanger (Du 150): 95.
  • Temperature at the inlet to the heated side, °C. E8 (Du 200) exchanger interchangeable with ARES: 60. E8-X150 heat exchanger (Du 150): 5.
  • Temperature at the outlet on the hot side, °C. E8 (Du 200) exchanger interchangeable with ARES: 116,7. E8-X150 heat exchanger (Du 150): 70.

If volume is your priority, E8 (Du 200) exchanger interchangeable with ARES has the larger stated capacity. Confirm the working load for your product.

Request a quote

Country

Cehmash stores your request. Only the catalogue administrator can view your contact details.

Request supplier quotes

Send one request to all selected companies. Replies appear in your account. Suppliers cannot see your email or phone number.

Equipment requested

Loading…

Recipients
Delivery country