Frozen, bullet and Vegetable processing and shock freezing line
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
| Highlighted rows show differences | ![]() | ![]() | ![]() | |
|---|---|---|---|---|
| Manufacturer | Matsuyama Marusan | Tecnopool-R | ZHEJIANG GUANFENG FOOD MACHINERY CO. LTD | AGRO-PROM-HOLOD |
| Manufacturer country | Japan | Russia | China | Russia |
| Equipment type | Rapid freezer | Rapid freezer | Rapid freezer | Rapid freezer |
| Throughput, kg/h | — | — | 5,000 | — |
| Power, kW | — | — | 245 | — |
| Objective | Drinks, cocktails, sherbets, musses, jelly, cakes | — | — | — |
| Save Method | Freezing at temperatures below -18 °C. | — | — | — |
| Volume | 1 kg | — | — | — |
| Country of origin | Japan (Echime Prefecture) | — | — | — |
| Taste period | 3 years since production | — | — | — |
| Note column | Please use it as soon as possible after thawing. | — | — | — |
| Container roll-over, for loading into the technology line reception bunker | — | 1 | — | — |
| Truck, wash and reception bunker transporter | — | 1 | — | — |
| Car wash | — | 1 | — | — |
| Bath-room discharge truck | — | 1 | — | — |
| root-cleaning machine | — | 1 | — | — |
| Product inspection transporter | — | 1 | — | — |
| The Corneberry Cut "Lomtic, Stolbik, Cube" | — | 1 | — | — |
| Blanshire of vegetables with transshipment line to chiller | — | 1 | — | — |
| Vegetable cooler after blanche | — | 1 | — | — |
| Wagon decoupling transporter | — | 1 | — | — |
| Vibration transporter | — | 1 | — | — |
| Sulphation machine | — | 1 | — | — |
| TECNO-FLU fluidizer | — | 1 | — | — |
| Refrigerated compressor-condensing unit | — | 1 | — | — |
| Product | — | Ratio | — | — |
| Green peas | — | 1 | — | — |
| Beans (cut 15-30 mm) | — | 0,85 | — | — |
| Corn (40-50 mm in kidneys) | — | 0,3 | — | — |
| Corn (grain) | — | 0,95 | — | — |
| Colour cabbage (20-50 mm) | — | 0,7 | — | — |
| Asparagus (cut 25 mm) | — | 0,7 | — | — |
| Green peppers (cut by pieces) | — | 0,6 - 0,75 | — | — |
| Tomato (integral ~ 30 mm) | — | 0,4 | — | — |
| Mushrooms (integral 10 mm) | — | 0,6 | — | — |
| Carrots (10 mm cubes) | — | 0,8 | — | — |
| Potatoes ( 10 mm cubes) | — | 0,8 | — | — |
| Smodden red, black | — | 0,75 | — | — |
| Grapes ( ≤ 20 mm) | — | 0,7 | — | — |
| The redhead. | — | 0,7 | — | — |
| Cherries (with bones) | — | 0,7 | — | — |
| Malina | — | 0,5 | — | — |
| Strawberries ( ∙ 25 - 35 mm) | — | 0,7 | — | — |
| Plum (knock) | — | 0,6 | — | — |
| Strawberry and mango productivity | — | — | 5 000 kg/h | — |
| Duration of freezing | — | — | 12–60 min | — |
| Temperature at the centre of product at outlet | — | — | −18 °C | — |
| Air temperature of the chamber | — | — | −33 ± 2 °C | — |
| Belt width | — | — | 1 250 mm | — |
| Dimensions | — | — | 31.5 × 4.3 × 4.16 m | — |
| Category Parameter | — | — | Details of specific parameters | — |
| Processing Capacity | — | — | 5000 Kg / h (for strawberry,mango dices ) | — |
| Dimension of Quick-Freezer Freezing Chamber | — | — | Length 29.5m × Width 4.3m × Height 4.03m | — |
| Overall Dimension of Quick-Freezer | — | — | Length 31.5m × Width 4.3m × Height 4.16m | — |
| Freezing time | — | — | 12-60min (adjustable via frequency conversion) | — |
| Flow temperature | — | — | +25 °C | — |
| Temperature of the unloading centre | — | — | -18 °C | — |
| Air Temperature in Freezing Chamber | — | — | -33±2 °C | — |
| Width of conveyor tape | — | — | 1250 mm | — |
| Conveyor Belt Reduction Motor | — | — | Equipped with frequency conversion speed regulation; 2 reducers in total | — |
| Special Quick-Freezing Centrifugal Fans | — | — | 17 sets in total (with high wind pressure, anti-vibration design) | — |
| Mesh Belt Vibration Chain Device | — | — | 13 sets in total, each controlled independently | — |
| Complete aluminium evaporators | — | — | Total 6 sets | — |
| Mesh Belt Cleaning and Drying Device | — | — | 1 set | — |
| Cooling Capacity Required for Quick-Freezing | — | — | 840 kW (working state: +35 °C/-42 °C) | — |
| Method of defrosting | — | — | Water washing, defrosting | — |
| Installed power | — | — | 245.0 kW | — |
| Host | — | — | — | Intended use |
| Compressor | — | — | — | Compresses coolant vapours, increasing pressure and temperature |
| Capacitor | — | — | — | He heats the refrigerant with air or water, the coolant moves to liquid phase |
| Extension valve (VET, ERT) | — | — | — | Reduces the refrigerant pressure before the evaporator and controls its delivery |
| Evaporator | — | — | — | Plastic or housing heat exchanger where water or glycol is cooled |
| Hydromodulosis | — | — | — | Pump, expansion tank and buffer — serve cooled liquid to consumers |
| Dryer filter, piping | — | — | — | Protect the contour from moisture and contamination |
| Automatics | — | — | — | Control keeps the temperature set, protects against freezing, overloading, loss of flow |
| Parameter | — | — | — | Why Important |
| Refrigeration capacity, kW | — | — | — | Main parameter: The heat load of the equipment or the flow and temperature difference of the liquid is considered as a function of the heat load of the equipment. |
| Liquid temperature at inlet and exit | — | — | — | Standard mode +12/+7 °C; for ice water and glycol, separate selection of compressor and evaporator |
| Type of coolant | — | — | — | Water, ethylene glycol or propylenglikol (for food production) Glycol reduces productivity by 5-15% |
| Type of capacitor | — | — | — | Air, water or sloppy — depending on the location, power and water contour |
| Position and climate | — | — | — | Street, roof or room; maximum summer and minimum winter air temperature |
| Operating mode | — | — | — | Continuous or shift operation and year-round or seasonal operation determine the choice of free cooling and redundancy. |
| Dimensions and noise level | — | — | — | Size of site, service passageway, noise limits near work places |
| Energy Efficiency (EER) | — | — | — | Determines the cost of electricity over the life cycle — often more important than the price of purchase |
| Work | — | — | — | Periodicity |
| Visual inspection, operation and accident log | — | — | — | Monthly |
| Cleaning of capacitor heat exchangers, filter verification | — | — | — | Quarterly |
| Control of refrigerant filling, leak search | — | — | — | Every six months |
| Electrical inspection, automation, glycol concentration | — | — | — | Annually |
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.