FL20C compact centrifugal pump and Chemical centrifugal pump of the HM ultrasound
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
| Highlighted rows show differences | ![]() | ![]() | ![]() | ![]() |
|---|---|---|---|---|
| Manufacturer | INOXMIMGRUP SL | UZPO TD | PISCHMASHSERVICE | UZPO TD |
| Model | FL20C | KHM | — | KHMs |
| Manufacturer country | Spain | Russia | Russia | Russia |
| Equipment type | Pump | Pump | Pump | Pump |
| Power, kW | — | 0.55 | 2.2 | 1.5 |
| HM engine power 6.3/20K5-1.5/2 | — | 1.5 kW | — | 1.5 kW |
| HM engine power 6.3/30K5-2.2/2 | — | 2.2 kW | — | 2.2 kW |
| HM engine power 12.5/50K5-5.5/2 | — | 5.5 kW | — | 5.5 kW |
| HM engine power 50/30K5-7.5/2 | — | 7.5 kW | — | 7.5 kW |
| Only 12 m3/h is required at a low altitude. | It ends at 10 m.a. | — | — | — |
| Needs more care or pressure | The industrial centrifugal pump FL30CI reaches a capacity of 90 m3/h. | — | — | — |
| You must strive for lower levels | Best auto-pierant like FL90CAI. | — | — | — |
| Apparatus | FL20C compact centrifugal pump | — | — | — |
| Telephone | +34 972 58 20 40Correu: | — | — | — |
| Delivery of HM 1.5/10K5-0.55/2 | — | 0.5–2.5 m³/h | — | — |
| FM engine power 1.5/10K5-0.55/2 | — | 0.55 kW | — | — |
| Supply of HM 1.5/15K5-0.55/2 | — | 0.1–2 m³/h | — | — |
| FM engine power 1.5/15K5-0.55/2 | — | 0.55 kW | — | — |
| Delivery of HM 1.5/20K5-0.75/2 | — | 1–3 m³/h | — | — |
| HM engine power 1.5/20K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 3.5/10K5-0.55/2 | — | 2.5–6 m³/h | — | — |
| FM engine power 3.5/10K5-0.55/2 | — | 0.55 kW | — | — |
| Supply of HM 3.5/20K5-0.75/2 | — | 2–6 m³/h | — | — |
| FM engine power 3.5/20K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 6.3/10K5-0.75/2 | — | 5–10 m³/h | — | — |
| HM engine power 6.3/10K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 6.3/20K5-1.5/2 | — | 4–10 m³/h | — | — |
| Supply of HM 6.3/25K5-1.5/2 | — | 4–10 m³/h | — | — |
| HM engine power 6.3/25K5-1.5/2 | — | 1.5 kW | — | — |
| Supply of HM 6.3/30K5-2.2/2 | — | 4–12 m³/h | — | — |
| Supply of HM 6.3/50K5-4.0/2 | — | 4–10 m³/h | — | — |
| HM engine power 6.3/50K5-4.0/2 | — | 4 kW | — | — |
| Delivery of HM 10/10K5-0.75/2 | — | 8–11 m³/h | — | — |
| HM engine power 10/10K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 12.5/20K5-1.5/2 | — | 8–16 m³/h | — | — |
| HM engine power 12.5/20K5-1.5/2 | — | 1.5 kW | — | — |
| Supply of HM 12.5/25K5-2.2/2 | — | 8–16 m³/h | — | — |
| HM engine power 12.5/25K5-2.2/2 | — | 2.2 kW | — | — |
| Supply of HM 12.5/30K5-3.0/2 | — | 8–18 m³/h | — | — |
| HM engine power 12.5/30K5-3.0/2 | — | 3 kW | — | — |
| Delivery of HM 12.5/50K5-5.5/2 | — | 8–16 m³/h | — | — |
| Delivery of HM 20/20K5-3.0/2 | — | 10–26 m³/h | — | — |
| HM engine power 20/20K5-3.0/2 | — | 3 kW | — | — |
| Delivery of HM 25/10K5-2.2/2 | — | 15–30 m³/h | — | — |
| HM engine power 25/10K5-2.2/2 | — | 2.2 kW | — | — |
| Delivery of HM 25/30K5-5.5/2 | — | 14–32 m³/h | — | — |
| HM engine power 25/30K5-5.5/2 | — | 5.5 kW | — | — |
| Delivery of HM 25/50K5-7.5/2 | — | 14–32 m³/h | — | — |
| HM engine power 25/50K5-7.5/2 | — | 7.5 kW | — | — |
| Delivery of HM 25/80K5-15.0/2 | — | 14–32 m³/h | — | — |
| HM power 25/80K5-15.0/2 | — | 15 kW | — | — |
| Delivery of HM 50/30K5-7.5/2 | — | 25–60 m³/h | — | — |
| Delivery of HM 50/50K5-15.0/2 | — | 30–60 m³/h | — | — |
| HM engine power 50/50K5-15.0/2 | — | 15 kW | — | — |
| Delivery of HM 80/30K5-11.0/2 | — | 60–80 m³/h | — | — |
| HM engine power 80/30K5-11.0/2 | — | 11 kW | — | — |
| Delivery of HM 80/50K5-18.5/2 | — | 50–85 m³/h | — | — |
| HM engine power 80/50K5-18.5/2 | — | 18.5 kW | — | — |
| Delivery of HM 100/25K5-15.0/2 | — | 80–110 m³/h | — | — |
| HM engine power 100/25K5-15.0/2 | — | 15 kW | — | — |
| Delivery of HM 100/30K5-18.5/2 | — | 80–110 m³/h | — | — |
| HM engine power 100/30K5-18.5/2 | — | 18.5 kW | — | — |
| Delivery of HM 100/50K5-22.0/2 | — | 80–110 m³/h | — | — |
| HM engine power 100/50K5-22.0/2 | — | 22 kW | — | — |
| Indicator | — | — | Value | — |
| Maximum density, kg/m3 not more than | — | — | 1095 | — |
| Viscosity maximum, m2/s, not more than | — | — | 4,46 *10-6 | — |
| Maximum temperature, 0C, not more than | — | — | 60 | — |
| Maximum temperature for spirit-containing liquids 0C, not more than | — | — | 35 | — |
| Maximum concentration of particulates not to exceed a maximum of non-abrasive, g/l | — | — | 150 | — |
| Acidity (organic acid per wine-coil), g/l, not more than | — | — | 28 | — |
| Of which: wine | — | — | 5 | — |
| Apple | — | — | 5 | — |
| Milk | — | — | 5 | — |
| Accumulated | — | — | 5 | — |
| Sulphuric acid content, mg/l, not more than | — | — | 300 | — |
| Free, mg/l, not more than | — | — | 30 | — |
| Abrasive particle content | — | — | not allowed | — |
| Type of pump | — | — | double piston | — |
| Delivery, m3/h | — | — | 10 ± 1,0 | — |
| Working pressure (outlet), MPa (kgs/cm2). | — | — | 0,32 (3,2)* | — |
| Double piston strokes of 1 min | — | — | 132 | — |
| Piston length, mm | — | — | 80 | — |
| Weight, kg | — | — | 145 | — |
| Power consumption in 1 hour of operation, kWh. | — | — | 1,8 ** | — |
| Installed power, kW | — | — | 2,2 | — |
| Length | — | — | 975 | — |
| Width | — | — | 430 | — |
| Height | — | — | 968 | — |
| Rectine-part materials in contact with product | — | — | Bronze 05Z5C5 GOST 613-79Stel 30 x 13 GOST 5632-72 Steel 08 x 18T1 GOST 5582-75 Rezina IR-34 | — |
| Amount of fixed resource before cap, h | — | — | 16 000 | — |
| Total service delivery time, normal hour | — | — | 0,006 | — |
| Fold-free, h | — | — | 400 | — |
| Average non-payment rate, h | — | — | 2 500 | — |
| Fixed service life, years | — | — | 8 | — |
| Diameter of suction and injection pipes, mm | — | — | 50 | — |
| Supply of HMs 6.3/20K5-1.5/2 | — | — | — | 3.5–9 m³/h |
| Delivery of HMs 12.5/20K5-2.2/2 | — | — | — | 8–14 m³/h |
| HM engine power 12.5/20K5-2.2/2 | — | — | — | 2.2 kW |
| Delivery of HMs 20/20K5-4.0/2 | — | — | — | 14–25 m³/h |
| HM engine power 20/20K5-4.0/2 | — | — | — | 4 kW |
| Delivery of HMs 6.3/30K5-2.2/2 | — | — | — | 4–10 m³/h |
| Delivery of HMs 12.5/30K5-3/2 | — | — | — | 8–14 m³/h |
| HM engine power 12.5/30K5-3/2 | — | — | — | 3 kW |
| Delivery of HMs 25/30K5-5.5/2 | — | — | — | 14–32 m³/h |
| HMs 25/30K5-5.5/2 engine power | — | — | — | 5.5 kW |
| Delivery of HMs 35/26K5-5.5/2 | — | — | — | 25–40 m³/h |
| HM engine power 35/26K5-5.5/2 | — | — | — | 5.5 kW |
| Delivery of HMs 35/25K5-7.5/2 | — | — | — | 25–40 m³/h |
| HM engine power 35/25K5-7.5/2 | — | — | — | 7.5 kW |
| Supply of HMs 6.3/50K5-5.5/2 | — | — | — | 4–10 m³/h |
| HM engine power 6.3/50K5-5.5/2 | — | — | — | 5.5 kW |
| Delivery of HMs 12.5/50K5-5.5/2 | — | — | — | 8–16 m³/h |
| Delivery of HMs 25/50K5-7.5/2 | — | — | — | 14–32 m³/h |
| HMs 25/50K5-7.5/2 engine power | — | — | — | 7.5 kW |
| Delivery of HMs 50/30K5-7.5/2 | — | — | — | 30–65 m³/h |
| Supply of HMs 50/45K5-15/2 | — | — | — | 30–70 m³/h |
| HM engine power 50/45K5-15/2 | — | — | — | 11 kW |
| Delivery of HMs 80/20K5-11/2 | — | — | — | 60–80 m³/h |
| HM engine power 80/20K5-11/2 | — | — | — | 11 kW |
| Delivery of HMs 100/50K5-30/2 | — | — | — | 80–120 m³/h |
| HMs 100/50K5-30/2 engine power | — | — | — | 30 kW |
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
Allow for the higher stated power of Pumping chemical pump of the ultrasound when sizing the electrical supply, and check the connection requirements.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.