1. Home
  2. Compare

Compare models

View summary
Highlighted rows show differences
Container, Tank, and Pallet Washing Machine Lurea KEB/KSB30
P86, P110, P510, P1010
KRS P 85, P 105 R, P 505 and P 1005 gastric washing machines
Equipment type shown for reference
IBC container (EU) washing through the throat
ManufacturerFELETIZIVILZIVILTEHNIKA VYSOKOGO DAVLENIIA
ModelKSB30P86——
Manufacturer countryBelarusRussiaRussiaRussia
Equipment typeWashing machineWashing machineWashing machineWashing machine
Volume, L4601,0001,000—
Power, kW152.22.2—
Configurations—P 86, P 110, P 510, P 1010P 85, P 105 R, P 505, P 1005—
ConfigurationRotary filter———
Maximum throughput by load type30 bin trolleys/h, 15 containers/h, 30 pallets/h———
Wash pump power15 kW———
Wash nozzles67———
Wash nozzle flow rate, combinedApprox. 870 L/min———
Rotary filter wash nozzles6———
Wash nozzle pressureApprox. 0.38 MPa———
Rinse nozzles29———
Rinse nozzle flow rate, combinedApprox. 100 L/min———
Rinse nozzle pressureApprox. 0.3 MPa———
Rotary filter feed pump power3 kW———
Detergent solution tank capacityApprox. 460 L———
Detergent tank insulationIncluded———
Detergent solution temperature controlElectric heating on KEB models, steam heating on KSB models———
Rinse water drainDirect to sewer, with no dilution or partial dilution of the detergent solution———
Automatic detergent dosingIncluded———
Rotary filter for detergent solutionIncluded———
Maximum detergent solution and rinse water temperature60 °C———
Drum drive power1.5 kW———
Detergent heating power, KEB3036 kW———
Rotary filter drive power0.12 kW———
Power, P 86—2.2 kW——
Power, P 110—4 kW——
Power, P 510—7.5 kW——
Power, P 1010—15 kW——
Voltage, P 86—240/400 V——
Voltage, P 110—240/400 V——
Voltage, P 510—240/400 V——
Voltage, P 1010—240/400 V——
Dok, P 86—5.5 A——
Dok, P 110—9.7 A——
Dok, P 510—16.4 A——
Dok, P 1010—29 A——
Weight, P 86—143 kg——
Weight, P 110—258 kg——
Weight, P 510—545 kg——
Weight, P 1010—870 kg——
Volume, P 86—1 m³——
Volume, P 110—1.5 m³——
Volume, P 510—2.5 m³——
Volume, P 1010—3.5 m³——
Water consumption 65 °C, P 86—0.9 m³/h——
Water consumption 65 °C, P 110—1.2 m³/h——
Water consumption 65 °C, P 510—1.4 m³/h——
Water consumption 65 °C, P 1010—1.8 m³/h——
Throughput, P 86—300 stomachs/hour——
Throughput, P 110—600 stomachs/hour——
Throughput, P 510—1,200 stomachs/hour——
Throughput, P 1010—2,400 stomachs/hour——
Power, P 85——2.2 kW—
Power, P 105 R——4 kW—
Power, P 505——7.5 kW—
Power, P 1005——15 kW—
Voltage, P 85——240/400 V—
Voltage, P 105 R——240/400 V—
Voltage, P 505——240/400 V—
Voltage, P 1005——240/400 V—
Dok, P 85——5.5 A—
Dok, P 105 R——9.7 A—
Dok, P 505——16.4 A—
Dok, P 1005——29 A—
Weight, P 85——135 kg—
Weight, P 105 R——245 kg—
Weight, P 505——520 kg—
Weight, P 1005——850 kg—
Volume, P 85——1 m³—
Volume, P 105 R——1.5 m³—
Volume, P 505——2.5 m³—
Volume, P 1005——3.5 m³—
Water consumption 65 °C, P 85——0.9 m³/h—
Water consumption 65 °C, P 105 R——1.2 m³/h—
Water consumption 65 °C, P 505——1.4 m³/h—
Water consumption 65 °C, P 1005——1.8 m³/h—
Throughput, P 85——15 stomachs/hour—
Throughput, P 105 R——30 stomachs/hour—
Throughput, P 505——60 stomachs/hour—
Throughput, P 1005——120 stomachs/hour—
Parameter———Value
Expenditure———21 L/min
Head pressure———≈ 130 bar
Power supply———3~400 V, 50 Hz, 5.5 kW
Cycle to Cube———8 min - 2018 Test
Water to Cube———UM 170L - Calculation for a model solution
Cubes in shifts———26 - 30 — Model Decision calculation
Water at the entrance———22 l/min, 1.5 - 6 bar, to 50 °C
Cubes on shift, one place.———E 35 — Calculation for the Model Decision
Cubes on shift, two seats.———E 49 — Calculation for the Model Decision
IBC Post: flow rate———21 L/min
Power supply of module———3~400 V, 50 Hz, 16.5 kW
Water on module———66 l/min, 2 - 6 bar, to 50 °C, D32 input
Pump module———in a room not less than +1 °C
Dimensions from the outside———~ 1,900 x 1,800 x 2,950 mm - Calculation for the model solution
Cube———1,200 x 1,000 mm in any orientation, 1000 and 1,250 l
Question———What to Choose
How many cubes per shift———Up to 26 - 30, occasionally a mobile kit; up to ~35 post 21 l/min; up to ~47 post 42 l/min; more than two seats per pump (EU 49 and ~ 76)
One product or many———One product: manual post with timer; different products and programmes: automatic
What was in the cube?———lycing, suspensions, syrup — basic performance; acids and chlorides — chemical execution and chamber; LVG and solvent paints — only after gas-freeing or on a separate project
People, acids work alongside you.———Hind chamber: Sprays and aerosol remain inside
Food and chemical cubes———in different posts; food not on mobile set
Is there a tank car wash nearby?———Yes - IBC post from the same pump module; no - separate post
Fats and oils———heating up to 60 °C - project
Winter and open area———pump module - room not less than +1 °C; post - warm box or heated panel

Pairwise comparison summaries

Request a quote

Country

Cehmash stores your request. Only the catalogue administrator can view your contact details.

Request supplier quotes

Send one request to all selected companies. Replies appear in your account. Suppliers cannot see your email or phone number.

Equipment requested

Loading…

Recipients
Delivery country