Sausage linker KOMPO and Automatic sausage garland divider
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
| Highlighted rows show differences | ![]() | ![]() | ![]() | ![]() |
|---|---|---|---|---|
| Manufacturer | KOMPO | KYOEI | FREY | EESC LLC |
| Model | — | — | WS420 | — |
| Manufacturer country | Belarus | Japan | Germany | Russia |
| Equipment type | Sausage linker | Sausage linker | Sausage linker | Sausage linker |
| Power, kW | 5 | — | 1 | — |
| Model | PLT-700 COMPE TYSTER | — | — | — |
| Nominal performance on artificial shells*, dose/min, | 700 | — | — | — |
| Dosage error, g, not more than * | ± 1,5 | — | — | — |
| Productivity control range, dose/min | 200 - 700 | — | — | — |
| :: Rolling number adjustment range, unit | 1 - 10 | — | — | — |
| Sizing range, mm | 16 - 36 | — | — | — |
| Length of finished product**, mm | 30 - 400 | — | — | — |
| Length of sausage gofro-hooks, mm, to | 430 | — | — | — |
| Height from chin to floor, mm | 1030 ± 50 | — | — | — |
| Product temperature range, °C | From -4 to +20 | — | — | — |
| Power supply, V | 400B/50 Hz | — | — | — |
| Power consumed, kW, not more than | 5 | — | — | — |
| Sizes: length/width/height, mm, not more than | 1800/800/1650 | — | — | — |
| Chicken diameters, mm | 10; 11; 12; 14; 16; 18; 20 | — | — | — |
| Net weight, kg, not more than | 400 | — | — | — |
| Average full-time service, years or more | 6 | — | — | — |
| Increases productivity; high accuracy of weight and length portionation | Automatic stopping of line at the end of artificial casing; stop function after a given number of portions; counter of developed portions; hanging and removing hangers with the intended step (using together with | — | — | — |
| Intended use | — | Automatic separation of sausages by cross-section(s) with containment | — | — |
| Type of product | — | Sausage, sausage, small-diameter sausage | — | — |
| Type of envelope | — | Natural, collagen, cellulose, polyamide | — | — |
| Diameter of the envelope | — | Ø 12–32 mm | — | — |
| Throughput | — | Up to 80 m/min | — | — |
| Cut Speed | — | Up to 1,300 incisions/min | — | — |
| Type of cutting | — | Mechanical separation by twist | — | — |
| Type of product delivery | — | Automatic line delivery | — | — |
| Control type | — | Bottle | — | — |
| Housing material | — | stainless steel | — | — |
| Voltage | — | 220 V | — | — |
| Installed power | — | 120 W | — | — |
| Air pressure | — | 5–7 bar | — | — |
| Dimensions (D×SxV) | — | 425 × 570 × 480 mm | — | — |
| Weight | — | ≈36 kg | — | — |
| Features | — | Segregation without damage to the casing, high speed of operation, compactness | — | — |
| Additional functions | — | Speed and separation adjustment, integration into the sausage line | — | — |
| Technical specifications | — | — | WS420 FREE | — |
| Industrial administration | — | — | 5.7' TFT colour display | — |
| Max cutting rate, per cent | — | — | 420 | — |
| Diameter of sausage, mm | — | — | 14-23 | — |
| Sausage length, mm | — | — | >25 | — |
| Max. tape speed, m/min | — | — | 35-200 | — |
| Compressed air, min bar | — | — | 6 | — |
| Compressed air connection | — | — | DIN ISO 8573-1 Class 2 | — |
| Air consumption (at 6 bar at max. cut-off speed), l/min | — | — | 6 | — |
| Power consumption, kW | — | — | 1 | — |
| Voltage, B, Hz | — | — | 230, 50/60 | — |
| Weight with shell, kg | — | — | ~70 | — |
| Operating height, mm | — | — | ~ 900 to 1050 | — |
| Dimensions with shell, D x T x min/max height, mm | — | — | 440 × 550 × 1322/1472 | — |
| RE15T | — | — | — | Milk separation 1,500 l/h · Normalization 2,500 l/h · Cleaning 2,500 l/h · Serum separation 2,500 l/h · Drive - Reductor · 5.5 kW |
| RE25TE | — | — | — | Segregation of milk 2,500 l/h · Normalization of 3,500 l/h · Cleaning of 3,500 l/h · separation of serum 3,500 l/h · Drive - Cutter · 7.5 kW |
| RE35TE | — | — | — | Separating of milk 3,500 l/h · Normalization of 5,000 l/h · Cleaning of 5,000 l/h · separation of serum 5,000 l/h · Drive - Reductor · 7.5 kW |
| RE50T | — | — | — | Milk separation 5,000 l/h · normalization 7,500 l/h · cleaning 7,500 l/h · serum separation 7,500 l/h · drive - control · 11 kW |
| RE70TE | — | — | — | Milk separation 7,000 l/h · Normalization 10,000 l/h · Cleaning 10,000 l/h · Serum separation 10,000 l/h · Drive - Reductor 15 kW |
| RE100TE | — | — | — | Milk separation 10,000 l/h · normalization 15,000 l/h · clean 15,000 l/h · serum separation 10,000 l/h · drive - control 15 kW |
| RE120T | — | — | — | Milk separation 12,000 l/h · Normalization 18,000 l/h · Cleaning 18,000 l/h · Serum separation 13,000 l/h · Drive - Reductor · 18.5 kW |
| RE150TE | — | — | — | Segregation of milk 15,000 l/h · Normalization of 20,000 l/h · Cleaning of 20,000 l/h · separation of serum 15,000 l/h · Drive - Remittance · Power 22 kW |
| RE150T | — | — | — | Milk separation 15,000 l/h · Normalization 22,500 L/h · Cleaning 22 500 L/h · Serum separation 22 500 L/h · Drive - Reductor 22 kW |
| RE200T | — | — | — | Separating of milk 20,000 l/h · Normalization of 30,000 l/h · Cleaning of 30,000 l/h · separation of serum 25,000 l/h · Drive - Reductor 30 kW |
| RE250T | — | — | — | Milk separation 25,000 l/h · Normalization 35,000 l/h · Cleaning 35,000 l/h · Serum separation 30,000 l/h · Drive - belt power 30 - 37 kW |
| RE350T | — | — | — | Segregation of milk 35,000 l/h · Normalization of 50,000 l/h · Cleaning 50,000 l/h · separation of serum 35,000 l/h · Drive - belt · power 37 - 45 kW |
| RE400T | — | — | — | Separating of milk 40,000 l/h · Normalization of 50,000 l/h · Cleaning 50,000 l/h · separation of serum 40,000 l/h · Drive - Remittance · Power 44 - 55 kW |
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
Allow for the higher stated power of Sausage linker KOMPO when sizing the electrical supply, and check the connection requirements.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.