KO-600 cooling container and Vegetable processing and shock freezing line
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
| Highlighted rows show differences | ![]() | ![]() | ![]() | |
|---|---|---|---|---|
| Manufacturer | FMG | Tecnopool-R | ZHEJIANG GUANFENG FOOD MACHINERY CO. LTD | AGRO-PROM-HOLOD |
| Manufacturer country | Russia | Russia | China | Russia |
| Equipment type | Rapid freezer | Rapid freezer | Rapid freezer | Rapid freezer |
| Throughput, kg/h | — | — | 5,000 | — |
| Power, kW | 5.5 | — | 245 | — |
| Dimensions | Depends on the number of sections | — | 31.5 × 4.3 × 4.16 m | — |
| Conveyor width | 600 mm | — | — | — |
| Voltage | 380 V | — | — | — |
| Power | 5.5 kW | — | — | — |
| Size of one section | 1900/950/1100 mm | — | — | — |
| Extension length | 900 mm | — | — | — |
| Length of the tension section | 800 mm | — | — | — |
| Speed of tape | 0.5-2.5/1-4 m/min | — | — | — |
| Container roll-over, for loading into the technology line reception bunker | — | 1 | — | — |
| Truck, wash and reception bunker transporter | — | 1 | — | — |
| Car wash | — | 1 | — | — |
| Bath-room discharge truck | — | 1 | — | — |
| root-cleaning machine | — | 1 | — | — |
| Product inspection transporter | — | 1 | — | — |
| The Corneberry Cut "Lomtic, Stolbik, Cube" | — | 1 | — | — |
| Blanshire of vegetables with transshipment line to chiller | — | 1 | — | — |
| Vegetable cooler after blanche | — | 1 | — | — |
| Wagon decoupling transporter | — | 1 | — | — |
| Vibration transporter | — | 1 | — | — |
| Sulphation machine | — | 1 | — | — |
| TECNO-FLU fluidizer | — | 1 | — | — |
| Refrigerated compressor-condensing unit | — | 1 | — | — |
| Product | — | Ratio | — | — |
| Green peas | — | 1 | — | — |
| Beans (cut 15-30 mm) | — | 0,85 | — | — |
| Corn (40-50 mm in kidneys) | — | 0,3 | — | — |
| Corn (grain) | — | 0,95 | — | — |
| Colour cabbage (20-50 mm) | — | 0,7 | — | — |
| Asparagus (cut 25 mm) | — | 0,7 | — | — |
| Green peppers (cut by pieces) | — | 0,6 - 0,75 | — | — |
| Tomato (integral ~ 30 mm) | — | 0,4 | — | — |
| Mushrooms (integral 10 mm) | — | 0,6 | — | — |
| Carrots (10 mm cubes) | — | 0,8 | — | — |
| Potatoes ( 10 mm cubes) | — | 0,8 | — | — |
| Smodden red, black | — | 0,75 | — | — |
| Grapes ( ≤ 20 mm) | — | 0,7 | — | — |
| The redhead. | — | 0,7 | — | — |
| Cherries (with bones) | — | 0,7 | — | — |
| Malina | — | 0,5 | — | — |
| Strawberries ( ∙ 25 - 35 mm) | — | 0,7 | — | — |
| Plum (knock) | — | 0,6 | — | — |
| Strawberry and mango productivity | — | — | 5 000 kg/h | — |
| Duration of freezing | — | — | 12–60 min | — |
| Temperature at the centre of product at outlet | — | — | −18 °C | — |
| Air temperature of the chamber | — | — | −33 ± 2 °C | — |
| Belt width | — | — | 1 250 mm | — |
| Category Parameter | — | — | Details of specific parameters | — |
| Processing Capacity | — | — | 5000 Kg / h (for strawberry,mango dices ) | — |
| Dimension of Quick-Freezer Freezing Chamber | — | — | Length 29.5m × Width 4.3m × Height 4.03m | — |
| Overall Dimension of Quick-Freezer | — | — | Length 31.5m × Width 4.3m × Height 4.16m | — |
| Freezing time | — | — | 12-60min (adjustable via frequency conversion) | — |
| Flow temperature | — | — | +25 °C | — |
| Temperature of the unloading centre | — | — | -18 °C | — |
| Air Temperature in Freezing Chamber | — | — | -33±2 °C | — |
| Width of conveyor tape | — | — | 1250 mm | — |
| Conveyor Belt Reduction Motor | — | — | Equipped with frequency conversion speed regulation; 2 reducers in total | — |
| Special Quick-Freezing Centrifugal Fans | — | — | 17 sets in total (with high wind pressure, anti-vibration design) | — |
| Mesh Belt Vibration Chain Device | — | — | 13 sets in total, each controlled independently | — |
| Complete aluminium evaporators | — | — | Total 6 sets | — |
| Mesh Belt Cleaning and Drying Device | — | — | 1 set | — |
| Cooling Capacity Required for Quick-Freezing | — | — | 840 kW (working state: +35 °C/-42 °C) | — |
| Method of defrosting | — | — | Water washing, defrosting | — |
| Installed power | — | — | 245.0 kW | — |
| Host | — | — | — | Intended use |
| Compressor | — | — | — | Compresses coolant vapours, increasing pressure and temperature |
| Capacitor | — | — | — | He heats the refrigerant with air or water, the coolant moves to liquid phase |
| Extension valve (VET, ERT) | — | — | — | Reduces the refrigerant pressure before the evaporator and controls its delivery |
| Evaporator | — | — | — | Plastic or housing heat exchanger where water or glycol is cooled |
| Hydromodulosis | — | — | — | Pump, expansion tank and buffer — serve cooled liquid to consumers |
| Dryer filter, piping | — | — | — | Protect the contour from moisture and contamination |
| Automatics | — | — | — | Control keeps the temperature set, protects against freezing, overloading, loss of flow |
| Parameter | — | — | — | Why Important |
| Refrigeration capacity, kW | — | — | — | Main parameter: The heat load of the equipment or the flow and temperature difference of the liquid is considered as a function of the heat load of the equipment. |
| Liquid temperature at inlet and exit | — | — | — | Standard mode +12/+7 °C; for ice water and glycol, separate selection of compressor and evaporator |
| Type of coolant | — | — | — | Water, ethylene glycol or propylenglikol (for food production) Glycol reduces productivity by 5-15% |
| Type of capacitor | — | — | — | Air, water or sloppy — depending on the location, power and water contour |
| Position and climate | — | — | — | Street, roof or room; maximum summer and minimum winter air temperature |
| Operating mode | — | — | — | Continuous or shift operation and year-round or seasonal operation determine the choice of free cooling and redundancy. |
| Dimensions and noise level | — | — | — | Size of site, service passageway, noise limits near work places |
| Energy Efficiency (EER) | — | — | — | Determines the cost of electricity over the life cycle — often more important than the price of purchase |
| Work | — | — | — | Periodicity |
| Visual inspection, operation and accident log | — | — | — | Monthly |
| Cleaning of capacitor heat exchangers, filter verification | — | — | — | Quarterly |
| Control of refrigerant filling, leak search | — | — | — | Every six months |
| Electrical inspection, automation, glycol concentration | — | — | — | Annually |
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
Compare the values for dimensions when choosing between the two models. Request throughput data for your product.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.