1. Home
  2. Compare

Compare models

View summary
Highlighted rows show differences
Equipment type shown for reference
Washing equipment
P86, P110, P510, P1010
KRS P 85, P 105 R, P 505 and P 1005 gastric washing machines
Equipment type shown for reference
IBC container (EU) washing through the throat
ManufacturerGRASSELLI NFSZIVILZIVILTEHNIKA VYSOKOGO DAVLENIIA
Model—P86——
Manufacturer countryRussiaRussiaRussiaRussia
Equipment typeWashing machineWashing machineWashing machineWashing machine
Volume, L—1,0001,000—
Power, kW—2.22.2—
Configurations—P 86, P 110, P 510, P 1010P 85, P 105 R, P 505, P 1005—
What kind of washing equipment do you propose for food production?We offer a wide range of professional washing equipment: boxes, trays, carts and frames, uniforms, palette cleaning facilities, meat carts and drawers washing devices, and equipment———
What's the specialty of washing machines for pans and boxes?The equipment is modularly designed to enable it to be flexible and adapted to the different production conditions and specific tasks of your enterprise.———
How does the knife and glove washing equipment work?This is an innovative solution for high-efficiency sanitation based on temperature activation of pathogens, which guarantees maximum hygiene and safety in food production.———
What options are available for washing the pill?We propose solutions for batch cleaning in special cupboards or a clean-up, with vertical or horizontal washing depending on your needs.———
What are the sanitary locks and sole disinfectors for?Sanitation locks and access control solutions are necessary to ensure strict sanitary standards and prevent contamination from the street or adjacent areas from becoming a net food production.———
Why should we use low pressure foam cleaners?Low pressure purging is an ideal and safe solution to meet the most modern and stringent hygiene requirements in food plants.———
Power, P 86—2.2 kW——
Power, P 110—4 kW——
Power, P 510—7.5 kW——
Power, P 1010—15 kW——
Voltage, P 86—240/400 V——
Voltage, P 110—240/400 V——
Voltage, P 510—240/400 V——
Voltage, P 1010—240/400 V——
Dok, P 86—5.5 A——
Dok, P 110—9.7 A——
Dok, P 510—16.4 A——
Dok, P 1010—29 A——
Weight, P 86—143 kg——
Weight, P 110—258 kg——
Weight, P 510—545 kg——
Weight, P 1010—870 kg——
Volume, P 86—1 m³——
Volume, P 110—1.5 m³——
Volume, P 510—2.5 m³——
Volume, P 1010—3.5 m³——
Water consumption 65 °C, P 86—0.9 m³/h——
Water consumption 65 °C, P 110—1.2 m³/h——
Water consumption 65 °C, P 510—1.4 m³/h——
Water consumption 65 °C, P 1010—1.8 m³/h——
Throughput, P 86—300 stomachs/hour——
Throughput, P 110—600 stomachs/hour——
Throughput, P 510—1,200 stomachs/hour——
Throughput, P 1010—2,400 stomachs/hour——
Power, P 85——2.2 kW—
Power, P 105 R——4 kW—
Power, P 505——7.5 kW—
Power, P 1005——15 kW—
Voltage, P 85——240/400 V—
Voltage, P 105 R——240/400 V—
Voltage, P 505——240/400 V—
Voltage, P 1005——240/400 V—
Dok, P 85——5.5 A—
Dok, P 105 R——9.7 A—
Dok, P 505——16.4 A—
Dok, P 1005——29 A—
Weight, P 85——135 kg—
Weight, P 105 R——245 kg—
Weight, P 505——520 kg—
Weight, P 1005——850 kg—
Volume, P 85——1 m³—
Volume, P 105 R——1.5 m³—
Volume, P 505——2.5 m³—
Volume, P 1005——3.5 m³—
Water consumption 65 °C, P 85——0.9 m³/h—
Water consumption 65 °C, P 105 R——1.2 m³/h—
Water consumption 65 °C, P 505——1.4 m³/h—
Water consumption 65 °C, P 1005——1.8 m³/h—
Throughput, P 85——15 stomachs/hour—
Throughput, P 105 R——30 stomachs/hour—
Throughput, P 505——60 stomachs/hour—
Throughput, P 1005——120 stomachs/hour—
Parameter———Value
Expenditure———21 L/min
Head pressure———≈ 130 bar
Power supply———3~400 V, 50 Hz, 5.5 kW
Cycle to Cube———8 min - 2018 Test
Water to Cube———UM 170L - Calculation for a model solution
Cubes in shifts———26 - 30 — Model Decision calculation
Water at the entrance———22 l/min, 1.5 - 6 bar, to 50 °C
Cubes on shift, one place.———E 35 — Calculation for the Model Decision
Cubes on shift, two seats.———E 49 — Calculation for the Model Decision
IBC Post: flow rate———21 L/min
Power supply of module———3~400 V, 50 Hz, 16.5 kW
Water on module———66 l/min, 2 - 6 bar, to 50 °C, D32 input
Pump module———in a room not less than +1 °C
Dimensions from the outside———~ 1,900 x 1,800 x 2,950 mm - Calculation for the model solution
Cube———1,200 x 1,000 mm in any orientation, 1000 and 1,250 l
Question———What to Choose
How many cubes per shift———Up to 26 - 30, occasionally a mobile kit; up to ~35 post 21 l/min; up to ~47 post 42 l/min; more than two seats per pump (EU 49 and ~ 76)
One product or many———One product: manual post with timer; different products and programmes: automatic
What was in the cube?———lycing, suspensions, syrup — basic performance; acids and chlorides — chemical execution and chamber; LVG and solvent paints — only after gas-freeing or on a separate project
People, acids work alongside you.———Hind chamber: Sprays and aerosol remain inside
Food and chemical cubes———in different posts; food not on mobile set
Is there a tank car wash nearby?———Yes - IBC post from the same pump module; no - separate post
Fats and oils———heating up to 60 °C - project
Winter and open area———pump module - room not less than +1 °C; post - warm box or heated panel

Pairwise comparison summaries

Request a quote

Country

Cehmash stores your request. Only the catalogue administrator can view your contact details.

Request supplier quotes

Send one request to all selected companies. Replies appear in your account. Suppliers cannot see your email or phone number.

Equipment requested

Loading…

Recipients
Delivery country