EMD – PUMP frequency pump converters
Zh6-VNP-10/32 piston pump
ManufacturerINNOVACIONNYE RESHENIYAUZPO TDPISCHMASHSERVICEUZPO TD
Model—KHM—KHMs
Manufacturer countryRussiaRussiaRussiaRussia
Equipment typePumpPumpPumpPump
Power, kW—0.552.21.5
HM engine power 6.3/20K5-1.5/2—1.5 kW—1.5 kW
HM engine power 6.3/30K5-2.2/2—2.2 kW—2.2 kW
HM engine power 12.5/50K5-5.5/2—5.5 kW—5.5 kW
HM engine power 50/30K5-7.5/2—7.5 kW—7.5 kW
Method of electric motor controlV/F – Volt frequency control (scaling)———
Frequency task discretionDigital: 0.01 HZA: 0.1% of maximum frequency———
Speeding/braking time4 speed/braking option: 0 ...6000 sec———
PID RegulatorIn-line PID Regulator with time-starved capability———
Programme modeTarget up to 15 preset speeds included in the programme———
Pulse counterInstalled pulse counter (up to 250 Hz)———
TimerTwo built-in timers: 1 Timer: 0...10.0 sec step 0.1 sec timer: 0 ...100 sec step 1 sec———
Time managementManual increase in moment within 0...20 per cent of nominal moment———
Discrete entrances8 Multifunctional Discretionary Entrances (NPN)———
Discrete exits8 cascade control (NO) relay exits: 3 A / ~250 V, 3 A / = 30 V3 multifunctional discrete exits:2 × transistor exits (NPN), 100 mA / = 24 V1 × relay exit (NO + NZ), 3 A / ~250 V, 3 A / = 30 V———
Analog entrances2 analog entrance:0...10 B / 0 ...20 mA———
Analog exits2 analog exits:0...10 B / 0...20 mA———
Communications interfaceRS-485, MODBUS ASCII/RTU Maximum Data Transmission Speed: 38400 bits/s———
Output frequency sourceControl remote, Analog entry, discrete entrance, RS-485 interface, speed control software———
Overloading120% of rated current for 60 seconds———
ProtectionIncreased/low voltage, current overload, short circuit and other———
Protection classIP20———
Environmental temperature-10...+40 °C (without frost)———
Relative humidityNot more than 95% (without condensate)———
Vibration levelMaximum acceleration amplitude 0.5g———
Refrigeration methodInstalled cooling fan———
Method of installationModels up to 132 kW: Wall fitting Model of capacity from 160 kW: Wall installation or cupboard performance———
Height of installation (absolute)1000 m above sea level (in case of increase, lower power of the equipment to be connected)———
Delivery of HM 1.5/10K5-0.55/2—0.5–2.5 m³/h——
FM engine power 1.5/10K5-0.55/2—0.55 kW——
Supply of HM 1.5/15K5-0.55/2—0.1–2 m³/h——
FM engine power 1.5/15K5-0.55/2—0.55 kW——
Delivery of HM 1.5/20K5-0.75/2—1–3 m³/h——
HM engine power 1.5/20K5-0.75/2—0.75 kW——
Supply of HM 3.5/10K5-0.55/2—2.5–6 m³/h——
FM engine power 3.5/10K5-0.55/2—0.55 kW——
Supply of HM 3.5/20K5-0.75/2—2–6 m³/h——
FM engine power 3.5/20K5-0.75/2—0.75 kW——
Supply of HM 6.3/10K5-0.75/2—5–10 m³/h——
HM engine power 6.3/10K5-0.75/2—0.75 kW——
Supply of HM 6.3/20K5-1.5/2—4–10 m³/h——
Supply of HM 6.3/25K5-1.5/2—4–10 m³/h——
HM engine power 6.3/25K5-1.5/2—1.5 kW——
Supply of HM 6.3/30K5-2.2/2—4–12 m³/h——
Supply of HM 6.3/50K5-4.0/2—4–10 m³/h——
HM engine power 6.3/50K5-4.0/2—4 kW——
Delivery of HM 10/10K5-0.75/2—8–11 m³/h——
HM engine power 10/10K5-0.75/2—0.75 kW——
Supply of HM 12.5/20K5-1.5/2—8–16 m³/h——
HM engine power 12.5/20K5-1.5/2—1.5 kW——
Supply of HM 12.5/25K5-2.2/2—8–16 m³/h——
HM engine power 12.5/25K5-2.2/2—2.2 kW——
Supply of HM 12.5/30K5-3.0/2—8–18 m³/h——
HM engine power 12.5/30K5-3.0/2—3 kW——
Delivery of HM 12.5/50K5-5.5/2—8–16 m³/h——
Delivery of HM 20/20K5-3.0/2—10–26 m³/h——
HM engine power 20/20K5-3.0/2—3 kW——
Delivery of HM 25/10K5-2.2/2—15–30 m³/h——
HM engine power 25/10K5-2.2/2—2.2 kW——
Delivery of HM 25/30K5-5.5/2—14–32 m³/h——
HM engine power 25/30K5-5.5/2—5.5 kW——
Delivery of HM 25/50K5-7.5/2—14–32 m³/h——
HM engine power 25/50K5-7.5/2—7.5 kW——
Delivery of HM 25/80K5-15.0/2—14–32 m³/h——
HM power 25/80K5-15.0/2—15 kW——
Delivery of HM 50/30K5-7.5/2—25–60 m³/h——
Delivery of HM 50/50K5-15.0/2—30–60 m³/h——
HM engine power 50/50K5-15.0/2—15 kW——
Delivery of HM 80/30K5-11.0/2—60–80 m³/h——
HM engine power 80/30K5-11.0/2—11 kW——
Delivery of HM 80/50K5-18.5/2—50–85 m³/h——
HM engine power 80/50K5-18.5/2—18.5 kW——
Delivery of HM 100/25K5-15.0/2—80–110 m³/h——
HM engine power 100/25K5-15.0/2—15 kW——
Delivery of HM 100/30K5-18.5/2—80–110 m³/h——
HM engine power 100/30K5-18.5/2—18.5 kW——
Delivery of HM 100/50K5-22.0/2—80–110 m³/h——
HM engine power 100/50K5-22.0/2—22 kW——
Indicator——Value—
Maximum density, kg/m3 not more than——1095—
Viscosity maximum, m2/s, not more than——4,46 *10-6—
Maximum temperature, 0C, not more than——60—
Maximum temperature for spirit-containing liquids 0C, not more than——35—
Maximum concentration of particulates not to exceed a maximum of non-abrasive, g/l——150—
Acidity (organic acid per wine-coil), g/l, not more than——28—
Of which: wine——5—
Apple——5—
Milk——5—
Accumulated——5—
Sulphuric acid content, mg/l, not more than——300—
Free, mg/l, not more than——30—
Abrasive particle content——not allowed—
Type of pump——double piston—
Delivery, m3/h——10 ± 1,0—
Working pressure (outlet), MPa (kgs/cm2).——0,32 (3,2)*—
Double piston strokes of 1 min——132—
Piston length, mm——80—
Weight, kg——145—
Power consumption in 1 hour of operation, kWh.——1,8 **—
Installed power, kW——2,2—
Length——975—
Width——430—
Height——968—
Rectine-part materials in contact with product——Bronze 05Z5C5 GOST 613-79Stel 30 x 13 GOST 5632-72 Steel 08 x 18T1 GOST 5582-75 Rezina IR-34—
Amount of fixed resource before cap, h——16 000—
Total service delivery time, normal hour——0,006—
Fold-free, h——400—
Average non-payment rate, h——2 500—
Fixed service life, years——8—
Diameter of suction and injection pipes, mm——50—
Supply of HMs 6.3/20K5-1.5/2———3.5–9 m³/h
Delivery of HMs 12.5/20K5-2.2/2———8–14 m³/h
HM engine power 12.5/20K5-2.2/2———2.2 kW
Delivery of HMs 20/20K5-4.0/2———14–25 m³/h
HM engine power 20/20K5-4.0/2———4 kW
Delivery of HMs 6.3/30K5-2.2/2———4–10 m³/h
Delivery of HMs 12.5/30K5-3/2———8–14 m³/h
HM engine power 12.5/30K5-3/2———3 kW
Delivery of HMs 25/30K5-5.5/2———14–32 m³/h
HMs 25/30K5-5.5/2 engine power———5.5 kW
Delivery of HMs 35/26K5-5.5/2———25–40 m³/h
HM engine power 35/26K5-5.5/2———5.5 kW
Delivery of HMs 35/25K5-7.5/2———25–40 m³/h
HM engine power 35/25K5-7.5/2———7.5 kW
Supply of HMs 6.3/50K5-5.5/2———4–10 m³/h
HM engine power 6.3/50K5-5.5/2———5.5 kW
Delivery of HMs 12.5/50K5-5.5/2———8–16 m³/h
Delivery of HMs 25/50K5-7.5/2———14–32 m³/h
HMs 25/50K5-7.5/2 engine power———7.5 kW
Delivery of HMs 50/30K5-7.5/2———30–65 m³/h
Supply of HMs 50/45K5-15/2———30–70 m³/h
HM engine power 50/45K5-15/2———11 kW
Delivery of HMs 80/20K5-11/2———60–80 m³/h
HM engine power 80/20K5-11/2———11 kW
Delivery of HMs 100/50K5-30/2———80–120 m³/h
HMs 100/50K5-30/2 engine power———30 kW