NPV-10/32 piston pump
ManufacturerPISCHMASHSERVICEUZPO TDUZPO TDINNOVACIONNYE RESHENIYA
Model—KHMKHMs—
Manufacturer countryRussiaRussiaRussiaRussia
Equipment typePumpPumpPumpPump
Power, kW2.20.551.5—
HM engine power 6.3/20K5-1.5/2—1.5 kW1.5 kW—
HM engine power 6.3/30K5-2.2/2—2.2 kW2.2 kW—
HM engine power 12.5/50K5-5.5/2—5.5 kW5.5 kW—
HM engine power 50/30K5-7.5/2—7.5 kW7.5 kW—
IndicatorValue———
Maximum density, kg/m3 not more than1095———
Viscosity maximum, m2/s, not more than4,46,10-6———
Maximum temperature, 0C, not more than60———
Maximum temperature for spirit-containing liquids 0C, not more than35———
Maximum concentration of particulates not to exceed a maximum of non-abrasive, g/l150———
Acidity (organic acid per wine-coil), g/l, not more than28———
Of which: wine5———
Apple5———
Milk5———
Accumulated5———
Sulphuric acid content, mg/l, not more than300———
Free, mg/l, not more than30———
Abrasive particle contentnot allowed———
Type of pumpdouble piston———
Delivery, m3/h10 ± 1,0———
Working pressure (outside), MPa (kgs/cm2)0,32 (3,2)*———
Number of double strokes of piston in mines78———
Products that are conforming to the productSteel 12 x 18H10T GOST 5632-72 AISI 304Stal 14 x 17H2 GOST 5632-72 Rezina IR-34———
Weight, kg190———
Set electric power (AIR90L4U3 1420 rpm), kW2,2———
Length1 315———
Width550———
Height950———
Amount of fixed resource before cap, h10 000———
Average working time, h, not more than2,0———
Fold-free, h400———
Fixed service life, years8———
Diameter of suction and injection pipes, mm50———
Delivery of HM 1.5/10K5-0.55/2—0.5–2.5 m³/h——
FM engine power 1.5/10K5-0.55/2—0.55 kW——
Supply of HM 1.5/15K5-0.55/2—0.1–2 m³/h——
FM engine power 1.5/15K5-0.55/2—0.55 kW——
Delivery of HM 1.5/20K5-0.75/2—1–3 m³/h——
HM engine power 1.5/20K5-0.75/2—0.75 kW——
Supply of HM 3.5/10K5-0.55/2—2.5–6 m³/h——
FM engine power 3.5/10K5-0.55/2—0.55 kW——
Supply of HM 3.5/20K5-0.75/2—2–6 m³/h——
FM engine power 3.5/20K5-0.75/2—0.75 kW——
Supply of HM 6.3/10K5-0.75/2—5–10 m³/h——
HM engine power 6.3/10K5-0.75/2—0.75 kW——
Supply of HM 6.3/20K5-1.5/2—4–10 m³/h——
Supply of HM 6.3/25K5-1.5/2—4–10 m³/h——
HM engine power 6.3/25K5-1.5/2—1.5 kW——
Supply of HM 6.3/30K5-2.2/2—4–12 m³/h——
Supply of HM 6.3/50K5-4.0/2—4–10 m³/h——
HM engine power 6.3/50K5-4.0/2—4 kW——
Delivery of HM 10/10K5-0.75/2—8–11 m³/h——
HM engine power 10/10K5-0.75/2—0.75 kW——
Supply of HM 12.5/20K5-1.5/2—8–16 m³/h——
HM engine power 12.5/20K5-1.5/2—1.5 kW——
Supply of HM 12.5/25K5-2.2/2—8–16 m³/h——
HM engine power 12.5/25K5-2.2/2—2.2 kW——
Supply of HM 12.5/30K5-3.0/2—8–18 m³/h——
HM engine power 12.5/30K5-3.0/2—3 kW——
Delivery of HM 12.5/50K5-5.5/2—8–16 m³/h——
Delivery of HM 20/20K5-3.0/2—10–26 m³/h——
HM engine power 20/20K5-3.0/2—3 kW——
Delivery of HM 25/10K5-2.2/2—15–30 m³/h——
HM engine power 25/10K5-2.2/2—2.2 kW——
Delivery of HM 25/30K5-5.5/2—14–32 m³/h——
HM engine power 25/30K5-5.5/2—5.5 kW——
Delivery of HM 25/50K5-7.5/2—14–32 m³/h——
HM engine power 25/50K5-7.5/2—7.5 kW——
Delivery of HM 25/80K5-15.0/2—14–32 m³/h——
HM power 25/80K5-15.0/2—15 kW——
Delivery of HM 50/30K5-7.5/2—25–60 m³/h——
Delivery of HM 50/50K5-15.0/2—30–60 m³/h——
HM engine power 50/50K5-15.0/2—15 kW——
Delivery of HM 80/30K5-11.0/2—60–80 m³/h——
HM engine power 80/30K5-11.0/2—11 kW——
Delivery of HM 80/50K5-18.5/2—50–85 m³/h——
HM engine power 80/50K5-18.5/2—18.5 kW——
Delivery of HM 100/25K5-15.0/2—80–110 m³/h——
HM engine power 100/25K5-15.0/2—15 kW——
Delivery of HM 100/30K5-18.5/2—80–110 m³/h——
HM engine power 100/30K5-18.5/2—18.5 kW——
Delivery of HM 100/50K5-22.0/2—80–110 m³/h——
HM engine power 100/50K5-22.0/2—22 kW——
Supply of HMs 6.3/20K5-1.5/2——3.5–9 m³/h—
Delivery of HMs 12.5/20K5-2.2/2——8–14 m³/h—
HM engine power 12.5/20K5-2.2/2——2.2 kW—
Delivery of HMs 20/20K5-4.0/2——14–25 m³/h—
HM engine power 20/20K5-4.0/2——4 kW—
Delivery of HMs 6.3/30K5-2.2/2——4–10 m³/h—
Delivery of HMs 12.5/30K5-3/2——8–14 m³/h—
HM engine power 12.5/30K5-3/2——3 kW—
Delivery of HMs 25/30K5-5.5/2——14–32 m³/h—
HMs 25/30K5-5.5/2 engine power——5.5 kW—
Delivery of HMs 35/26K5-5.5/2——25–40 m³/h—
HM engine power 35/26K5-5.5/2——5.5 kW—
Delivery of HMs 35/25K5-7.5/2——25–40 m³/h—
HM engine power 35/25K5-7.5/2——7.5 kW—
Supply of HMs 6.3/50K5-5.5/2——4–10 m³/h—
HM engine power 6.3/50K5-5.5/2——5.5 kW—
Delivery of HMs 12.5/50K5-5.5/2——8–16 m³/h—
Delivery of HMs 25/50K5-7.5/2——14–32 m³/h—
HMs 25/50K5-7.5/2 engine power——7.5 kW—
Delivery of HMs 50/30K5-7.5/2——30–65 m³/h—
Supply of HMs 50/45K5-15/2——30–70 m³/h—
HM engine power 50/45K5-15/2——11 kW—
Delivery of HMs 80/20K5-11/2——60–80 m³/h—
HM engine power 80/20K5-11/2——11 kW—
Delivery of HMs 100/50K5-30/2——80–120 m³/h—
HMs 100/50K5-30/2 engine power——30 kW—
Method of electric motor control———V/F – Volt frequency control (scaling)
Frequency task discretion———Digital: 0.01 HZA: 0.1% of maximum frequency
Speeding/braking time———4 speed/braking option: 0 ...6000 sec
PID Regulator———In-line PID Regulator with time-starved capability
Programme mode———Target up to 15 preset speeds included in the programme
Pulse counter———Installed pulse counter (up to 250 Hz)
Timer———Two built-in timers: 1 Timer: 0...10.0 sec step 0.1 sec timer: 0 ...100 sec step 1 sec
Time management———Manual increase in moment within 0...20 per cent of nominal moment
Discrete entrances———8 Multifunctional Discretionary Entrances (NPN)
Discrete exits———8 cascade control (NO) relay exits: 3 A / ~250 V, 3 A / = 30 V3 multifunctional discrete exits:2 × transistor exits (NPN), 100 mA / = 24 V1 × relay exit (NO + NZ), 3 A / ~250 V, 3 A / = 30 V
Analog entrances———2 analog entrance:0...10 B / 0 ...20 mA
Analog exits———2 analog exits:0...10 B / 0...20 mA
Communications interface———RS-485, MODBUS ASCII/RTU Maximum Data Transmission Speed: 38400 bits/s
Output frequency source———Control remote, Analog entry, discrete entrance, RS-485 interface, speed control software
Overloading———120% of rated current for 60 seconds
Protection———Increased/low voltage, current overload, short circuit and other
Protection class———IP20
Environmental temperature———-10...+40 °C (without frost)
Relative humidity———Not more than 95% (without condensate)
Vibration level———Maximum acceleration amplitude 0.5g
Refrigeration method———Installed cooling fan
Method of installation———Models up to 132 kW: Wall fitting Model of capacity from 160 kW: Wall installation or cupboard performance
Height of installation (absolute)———1000 m above sea level (in case of increase, lower power of the equipment to be connected)