Pump PISCHMASHSERVICE and Chemical centrifugal pump of the HM ultrasound
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
| Highlighted rows show differences | ![]() | ![]() | ![]() | ![]() |
|---|---|---|---|---|
| Manufacturer | PISCHMASHSERVICE | UZPO TD | UZPO TD | INNOVACIONNYE RESHENIYA |
| Model | — | KHM | KHMs | — |
| Manufacturer country | Russia | Russia | Russia | Russia |
| Equipment type | Pump | Pump | Pump | Pump |
| Power, kW | — | 0.55 | 1.5 | — |
| HM engine power 6.3/20K5-1.5/2 | — | 1.5 kW | 1.5 kW | — |
| HM engine power 6.3/30K5-2.2/2 | — | 2.2 kW | 2.2 kW | — |
| HM engine power 12.5/50K5-5.5/2 | — | 5.5 kW | 5.5 kW | — |
| HM engine power 50/30K5-7.5/2 | — | 7.5 kW | 7.5 kW | — |
| Pressure pressure, MPa (m) not less than | 0,5 (50) | — | — | — |
| Power of electric motor kW | Depends on pump performance | — | — | — |
| N, (vouch/min) | Depends on pump performance | — | — | — |
| Voltage, V | 380 | — | — | — |
| Diameter of intake/injection tubes, (mm) | Depends on the pump running | — | — | — |
| Delivery of HM 1.5/10K5-0.55/2 | — | 0.5–2.5 m³/h | — | — |
| FM engine power 1.5/10K5-0.55/2 | — | 0.55 kW | — | — |
| Supply of HM 1.5/15K5-0.55/2 | — | 0.1–2 m³/h | — | — |
| FM engine power 1.5/15K5-0.55/2 | — | 0.55 kW | — | — |
| Delivery of HM 1.5/20K5-0.75/2 | — | 1–3 m³/h | — | — |
| HM engine power 1.5/20K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 3.5/10K5-0.55/2 | — | 2.5–6 m³/h | — | — |
| FM engine power 3.5/10K5-0.55/2 | — | 0.55 kW | — | — |
| Supply of HM 3.5/20K5-0.75/2 | — | 2–6 m³/h | — | — |
| FM engine power 3.5/20K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 6.3/10K5-0.75/2 | — | 5–10 m³/h | — | — |
| HM engine power 6.3/10K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 6.3/20K5-1.5/2 | — | 4–10 m³/h | — | — |
| Supply of HM 6.3/25K5-1.5/2 | — | 4–10 m³/h | — | — |
| HM engine power 6.3/25K5-1.5/2 | — | 1.5 kW | — | — |
| Supply of HM 6.3/30K5-2.2/2 | — | 4–12 m³/h | — | — |
| Supply of HM 6.3/50K5-4.0/2 | — | 4–10 m³/h | — | — |
| HM engine power 6.3/50K5-4.0/2 | — | 4 kW | — | — |
| Delivery of HM 10/10K5-0.75/2 | — | 8–11 m³/h | — | — |
| HM engine power 10/10K5-0.75/2 | — | 0.75 kW | — | — |
| Supply of HM 12.5/20K5-1.5/2 | — | 8–16 m³/h | — | — |
| HM engine power 12.5/20K5-1.5/2 | — | 1.5 kW | — | — |
| Supply of HM 12.5/25K5-2.2/2 | — | 8–16 m³/h | — | — |
| HM engine power 12.5/25K5-2.2/2 | — | 2.2 kW | — | — |
| Supply of HM 12.5/30K5-3.0/2 | — | 8–18 m³/h | — | — |
| HM engine power 12.5/30K5-3.0/2 | — | 3 kW | — | — |
| Delivery of HM 12.5/50K5-5.5/2 | — | 8–16 m³/h | — | — |
| Delivery of HM 20/20K5-3.0/2 | — | 10–26 m³/h | — | — |
| HM engine power 20/20K5-3.0/2 | — | 3 kW | — | — |
| Delivery of HM 25/10K5-2.2/2 | — | 15–30 m³/h | — | — |
| HM engine power 25/10K5-2.2/2 | — | 2.2 kW | — | — |
| Delivery of HM 25/30K5-5.5/2 | — | 14–32 m³/h | — | — |
| HM engine power 25/30K5-5.5/2 | — | 5.5 kW | — | — |
| Delivery of HM 25/50K5-7.5/2 | — | 14–32 m³/h | — | — |
| HM engine power 25/50K5-7.5/2 | — | 7.5 kW | — | — |
| Delivery of HM 25/80K5-15.0/2 | — | 14–32 m³/h | — | — |
| HM power 25/80K5-15.0/2 | — | 15 kW | — | — |
| Delivery of HM 50/30K5-7.5/2 | — | 25–60 m³/h | — | — |
| Delivery of HM 50/50K5-15.0/2 | — | 30–60 m³/h | — | — |
| HM engine power 50/50K5-15.0/2 | — | 15 kW | — | — |
| Delivery of HM 80/30K5-11.0/2 | — | 60–80 m³/h | — | — |
| HM engine power 80/30K5-11.0/2 | — | 11 kW | — | — |
| Delivery of HM 80/50K5-18.5/2 | — | 50–85 m³/h | — | — |
| HM engine power 80/50K5-18.5/2 | — | 18.5 kW | — | — |
| Delivery of HM 100/25K5-15.0/2 | — | 80–110 m³/h | — | — |
| HM engine power 100/25K5-15.0/2 | — | 15 kW | — | — |
| Delivery of HM 100/30K5-18.5/2 | — | 80–110 m³/h | — | — |
| HM engine power 100/30K5-18.5/2 | — | 18.5 kW | — | — |
| Delivery of HM 100/50K5-22.0/2 | — | 80–110 m³/h | — | — |
| HM engine power 100/50K5-22.0/2 | — | 22 kW | — | — |
| Supply of HMs 6.3/20K5-1.5/2 | — | — | 3.5–9 m³/h | — |
| Delivery of HMs 12.5/20K5-2.2/2 | — | — | 8–14 m³/h | — |
| HM engine power 12.5/20K5-2.2/2 | — | — | 2.2 kW | — |
| Delivery of HMs 20/20K5-4.0/2 | — | — | 14–25 m³/h | — |
| HM engine power 20/20K5-4.0/2 | — | — | 4 kW | — |
| Delivery of HMs 6.3/30K5-2.2/2 | — | — | 4–10 m³/h | — |
| Delivery of HMs 12.5/30K5-3/2 | — | — | 8–14 m³/h | — |
| HM engine power 12.5/30K5-3/2 | — | — | 3 kW | — |
| Delivery of HMs 25/30K5-5.5/2 | — | — | 14–32 m³/h | — |
| HMs 25/30K5-5.5/2 engine power | — | — | 5.5 kW | — |
| Delivery of HMs 35/26K5-5.5/2 | — | — | 25–40 m³/h | — |
| HM engine power 35/26K5-5.5/2 | — | — | 5.5 kW | — |
| Delivery of HMs 35/25K5-7.5/2 | — | — | 25–40 m³/h | — |
| HM engine power 35/25K5-7.5/2 | — | — | 7.5 kW | — |
| Supply of HMs 6.3/50K5-5.5/2 | — | — | 4–10 m³/h | — |
| HM engine power 6.3/50K5-5.5/2 | — | — | 5.5 kW | — |
| Delivery of HMs 12.5/50K5-5.5/2 | — | — | 8–16 m³/h | — |
| Delivery of HMs 25/50K5-7.5/2 | — | — | 14–32 m³/h | — |
| HMs 25/50K5-7.5/2 engine power | — | — | 7.5 kW | — |
| Delivery of HMs 50/30K5-7.5/2 | — | — | 30–65 m³/h | — |
| Supply of HMs 50/45K5-15/2 | — | — | 30–70 m³/h | — |
| HM engine power 50/45K5-15/2 | — | — | 11 kW | — |
| Delivery of HMs 80/20K5-11/2 | — | — | 60–80 m³/h | — |
| HM engine power 80/20K5-11/2 | — | — | 11 kW | — |
| Delivery of HMs 100/50K5-30/2 | — | — | 80–120 m³/h | — |
| HMs 100/50K5-30/2 engine power | — | — | 30 kW | — |
| Method of electric motor control | — | — | — | V/F – Volt frequency control (scaling) |
| Frequency task discretion | — | — | — | Digital: 0.01 HZA: 0.1% of maximum frequency |
| Speeding/braking time | — | — | — | 4 speed/braking option: 0 ...6000 sec |
| PID Regulator | — | — | — | In-line PID Regulator with time-starved capability |
| Programme mode | — | — | — | Target up to 15 preset speeds included in the programme |
| Pulse counter | — | — | — | Installed pulse counter (up to 250 Hz) |
| Timer | — | — | — | Two built-in timers: 1 Timer: 0...10.0 sec step 0.1 sec timer: 0 ...100 sec step 1 sec |
| Time management | — | — | — | Manual increase in moment within 0...20 per cent of nominal moment |
| Discrete entrances | — | — | — | 8 Multifunctional Discretionary Entrances (NPN) |
| Discrete exits | — | — | — | 8 cascade control (NO) relay exits: 3 A / ~250 V, 3 A / = 30 V3 multifunctional discrete exits:2 × transistor exits (NPN), 100 mA / = 24 V1 × relay exit (NO + NZ), 3 A / ~250 V, 3 A / = 30 V |
| Analog entrances | — | — | — | 2 analog entrance:0...10 B / 0 ...20 mA |
| Analog exits | — | — | — | 2 analog exits:0...10 B / 0...20 mA |
| Communications interface | — | — | — | RS-485, MODBUS ASCII/RTU Maximum Data Transmission Speed: 38400 bits/s |
| Output frequency source | — | — | — | Control remote, Analog entry, discrete entrance, RS-485 interface, speed control software |
| Overloading | — | — | — | 120% of rated current for 60 seconds |
| Protection | — | — | — | Increased/low voltage, current overload, short circuit and other |
| Protection class | — | — | — | IP20 |
| Environmental temperature | — | — | — | -10...+40 °C (without frost) |
| Relative humidity | — | — | — | Not more than 95% (without condensate) |
| Vibration level | — | — | — | Maximum acceleration amplitude 0.5g |
| Refrigeration method | — | — | — | Installed cooling fan |
| Method of installation | — | — | — | Models up to 132 kW: Wall fitting Model of capacity from 160 kW: Wall installation or cupboard performance |
| Height of installation (absolute) | — | — | — | 1000 m above sea level (in case of increase, lower power of the equipment to be connected) |
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
Allow for the higher stated power of Pumping chemical pump of the ultrasound when sizing the electrical supply, and check the connection requirements.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.
For a direct comparison, obtain specifications for both machines using the same product and operating conditions.